Texas California Florida
Aligned Conflict Gap
Requirement Texas
IBC 2021 w/ amendments
California
CBC 2022 (Title 24)
Florida
FBC 2023 (8th ed.)
Corridor Width — Healthcare (I-2)
8'-0" min
Per IBC §407.4.1
8'-0" min + 44" clear
CBC adds clear width req
8'-0" min
Per FBC §407.4.1
Fire-Resistance Rating — Corridor Walls
1 hour
Per IBC §1020.1
1 hour
Per CBC §1020.1
1 hour
Per FBC §1020.1
Smoke Compartment Area
22,500 SF max
Per IBC §407.5.1
22,500 SF + 150' travel
CBC adds travel distance limit
22,500 SF max
Per FBC §407.5.1
Automatic Sprinkler System
Required — NFPA 13
All I-2 occupancies
Required — NFPA 13
All I-2 occupancies
Required — NFPA 13
All I-2 occupancies
Wind Load Design
ASCE 7-22
Standard reference
ASCE 7-22
Standard reference
FBC §1609 + HVHZ
High Velocity Hurricane Zone overlay
Seismic Design Category
SDC A-B (typical)
Low seismic risk
SDC D-F
High seismic risk — additional requirements
SDC A-B (typical)
Low seismic risk
Energy Code Compliance Path
IECC 2021 / 90.1-2019
Either compliance path
Title 24 Part 6
CA-specific energy code (stricter)
IECC 2021 / 90.1-2019
Either compliance path
Summary
6 aligned · 0 conflicts
3 aligned · 4 conflicts
Stricter in most categories
5 aligned · 1 conflict
HVHZ overlay for wind